Monday, March 16, 2015

Guaranteed Property Inspection & Mold Investigation Inc Receives 2014 Best Businesses of Irvine Award

Press Release

Press Release
FOR IMMEDIATE RELEASE
Guaranteed Property Inspection & Mold Investigation Inc Receives 2014 Best Businesses of Irvine Award
Irvine Award Program Honors the Achievement
Irvine, January 9, 2015 — Guaranteed Property Inspection & Mold Investigation Inc has been selected for the 2014 Best Businesses of Irvine Award in the Home Inspectors category by the Best Businesses of Irvine Award Program.
Each year, the Best Businesses of Irvine Award Program identifies companies that we believe have achieved exceptional marketing success in their local community and business category. These are local companies that enhance the positive image of small business through service to their customers and our community. These exceptional companies help make the Irvine area a great place to live, work and play.
Various sources of information were gathered and analyzed to choose the winners in each category. The 2014 Best Businesses of Irvine Award Program focuses on quality, not quantity. Winners are determined based on the information gathered both internally by the Best Businesses of Irvine Award Program and data provided by third parties.
About the Best Businesses of Irvine Award Program
The Best Businesses of Irvine Award Program is an annual awards program honoring the achievements and accomplishments of local businesses throughout the Irvine area. Recognition is given to those companies that have shown the ability to use their best practices and implemented programs to generate competitive advantages and long-term value.
The Best Businesses of Irvine Award Program was established to recognize the best of local businesses in our community. Our organization works exclusively with local business owners, trade groups, professional associations and other business advertising and marketing groups. Our mission is to recognize the small business community’s contributions to the U.S. economy.
SOURCE: Best Businesses of Irvine Award Program
CONTACT:
Best Businesses of Irvine Award Program
Email: PublicRelations@BestBusinesses.biz
URL: http://www.BestBusinesses.biz
###

Sunday, March 15, 2015

Results of Formaldehyde Testing of Building Liquidator Flooring

We have tested a number of homes for formaldehyde gas levels that have Building Liquidator flooring installed.

Our results so far show formaldehyde levels ranging from .095 ppm to .045 ppm.

These levels are  above California standard of .05 ppm., or within within the standard deviation. In addition, these levels are within the standard deviation of acceptable EPA levels of .1 ppm.

We have recommended that our clients take prompt action; e.g. removing the flooring promptly.

To test for formaldehyde in a home we use the following process that is conducted by a Certified Microbial Consultant. We charge $275 (in the Orange County area of California); which includes the test and written test results from an AHIA lab. Results take about 48 to 72 hours.


Formaldehyde Vapor Monitor

General
The Formaldehyde Vapor Monitor is used to measure personal exposure or room concentrations. This monitoring badge will be accepted in as accurate in any inspection or dispute, because it is validated for accuracy, and analyzed in an AIHA-LAP, LLC accredited laboratory.

Indoor Air Quality
For measurement of indoor air quality, The EPA and The American Lung Assoc. recommend a maximum level of 0.1 ppm; California recommend 0.05 ppm. Some people may be sensitive to lower levels. The monitoring badge is placed in a room with suspect flooring for about 24 hours. Then it will be accurate at a level of 0.003 ppm (3 parts per billion). For a 48 hour exposure, the minimum level is even lower.


OSHA Regulations
Each person who uses formaldehyde as a regular part of their job must have their exposure monitored periodically, according to OSHA regulations. 
There are two conditions that must be met to comply with the OSHA Standards for personal exposure in the workplace. First, the concentration for an 8 hour period must be less than 0.75 ppm. Second, the maximum exposure during any 15 minute interval must be less than 2.0 ppm. There is also an “action level” at 0.5 ppm for an 8 hour period. Above the action level more frequent monitoring is needed to avoid the need for protective equipment and for medical testing. 
The Formaldehyde Vapor Monitor meets OSHA accuracy requirements for both the full shift and short-term measurements.

Principle of Operation
Collection of formaldehyde vapor by diffusion in the monitor and collection on a chemical activated solid adsorbent. Analysis is done by methods validated for accuracy by The Occupational Safety & Health Administration (OSHA) and by The National Institute of Occupational Safety & Health (NIOSH).

Thursday, March 12, 2015

Formaldehyde Testing of Building Liquidators Flooring.

Yes we provide this type of testing.

The NIOSH approve testing cost is $195.

The test should be conducted for at least 24 hours.